10KVA-200KVA low frequency online ups
Advanced digital circuit system
Intelligent management
well-equipped protection
UPS
UPS:10KVA-200KVA low frequency online ups Full Intelligent Digital UPS(GP5310-GP53200)Application in kinds of grid environment, work with high stability. Each UPS capacity is from 10kva to 400kva, widely used in telecommunication, banks, negotiable securities, traffic, arms, security, electronics, industry, large enterprises and so on.
features:
1. Advanced digital circuit system 2. Intelligent management of batteries status3. Intelligent inspect and monitor UPS systems every second4. Intelligent communication tool remote control5. The sixth generation IGBT inverter technology6. High definition screen information management technology, humanity LCD display show directly UPS status and operation, data records in table format, and events records, also can change language by main menu.7. LED status shows operate steps and status directly.8. GP5300 series UPS use touch screen with excellent ageing resistance function and case dealed with fluorin and carbon technology, lead it is environmental and durable; the UPS adopts knock-down modular design, ensure it easy to maintain; It is with new advanced turbofan which can release heat well and save energy; It also use non-circumfluence controlled circuit;9. Excellent load characters can fulfill with suddenly change load from 0 to 100%, and no need to invert to bypass, ensure output stable and reliable.10. well-equipped protection for alarm function and excellent input&output Undervoltage overflow, input surge, phase failure, battery overcharge and over discharge , output overload short circuit , over heat and so on. 11. High quality active features, adopts instantaneous control method and virtual value response control and so on. This function realizes high active adjust and decrease output voltage degree of distortion.12. Three phase can equal stable voltage and control separately, in order to control instantaneous overload degree of equal, realize output imbalance 100% load.13. Optional input harmonic filter or Twelve-pulse rectifier, can restrain input harmonic pollution efficiently, improve UPS input power factor, and minish input harmonic current.14. Special set: can set UPS work status according to requirements of electric.
GP5310 ~ GP53200 series specification
Model
GP5310 ~ GP53200 series UPS
Capacity (VA)
10K
15K
20K
30K
40K
60K
80K
100K
120K
160K
200K
Noninal output capacity
8KW
12KW
16KW
24KW
32KW
48KW
64KW
80KW
96KW
128KW
160KW
Operate type
Double conversion online type
Input
voltage
220V/380, 230/400, 240/415V, ±25%
Phase
Three phase +N+G
Frequency
50Hz/60Hz±5%
Input power factor
0.95(with input filter)
Soft start
0-100% 5sec
Output
Voltage
220V/380, 230/400, 240/415V, ±1% (stable load), ±5%(active load)
Phase
Three phase +N+G
Frequency
50/60Hz (1±5%, AC mode), 50/60Hz (±1%, Battery mode)
Power factor
0.8
Output wave
Pure sine wave
Distortion
Linear load <3%, non linear load<5%
Battery voltage
Standard battery voltage
360V/384V
Floating charge
405V/432V
Terminal voltage
315V/336V
Charge current
1A-50A (Can calculate and set according to battery configuration software)
Maximum discharge current
28
42
56
85
113
169
225
282
338
381
507
Main Function
Active voltage change
0-100%±5%
Instant recover time
<10ms
Imbalance voltage
<±5%,<±1%( Balance load voltage)
Overload capacity
125%→10min,150%→1min
Static switch
Automatic
Protection
UPS over current, short circuit, battery low voltage, over heat
Cold method
Compel aeration ( temperature control mode)
Noise
60-65dB
Display
LED,LCD display
Communication port(Optional)
RS232, SNMP, dry-contact
Alarm
Alarm with buzzer and indicators
Environment
Temperature: 0-40C Humidity: 0-90%