Wednesday, June 29, 2011

marine load bank

Generator set intelligent testing system can test output power and load capacity exactly. Its main function is to test electrici
Main feature and function
It can test stable state three-phase voltage, current, active power, reactive power, apparent power, power factor, frequency, run duration of generating set and so on.
It has harmonic analysis function and power energy accumulation function. It can analyze voltage, 2-50 times harmonic capacity of current, total harmonic capacity.
It has setting test, fluctuating test, transient test (load increase quick, load decrease quick) ,and can test automatic max voltage, min. voltage, max current, min. current, max frequency, min. frequency and restoring time.
It is of powerful voltage oscillograph and photoelectricity isolate and RS485/RS232 com communication.
Not only it can display all stable state parameter, but also the load increase quickly, load decrease quickly, voltage, current, frequency curve, voltage curve, current harmonic curve and harmonic content.
Cooperating with software, It can achieve automatic testing all electricity parameter and form all kinds of chart, curve, and test report. The content of data is very abundant; the report form is of applicability. Data and report forms can be signed and changed format according to consumer’s need.
It is of four group load control functions. Its each group can control 25% load and combine four load forms of 25%, 50%, 75% and 100% or set oneself according to users’ need.
It is of load control function that can achieve the function of load increasing quickly and load decreasing quickly.
It is of loading inductive or capacitive load.(It is designed specially according consumers’ need)
Control function not only can be controlled automatically by PC, but also manual operated with panel hand.
It is configured three ways sensor interface of environment temperature, humidity and atmospheric pressure and can achieve automatically the measure of environment temperature, humidity and atmospheric pressure, display and upload(Consumer configures sensor by oneself).
We adopt power input mode of optimize subsection for it that can be set convenient and covered all power. (1kw—Max 120kw, 0.5Kva —50.5kvA).
It achieves intelligent control that can test automatic all kinds of parameter include dynamic parameters. It can provide scientific test measures for high-power generating set.
14. Cooling measures: forced air cooling.
15. Operation measure: load subsection control (single-pole double throw switch, controlled by contactor) can meet any power combination in rating power.

No comments:

Post a Comment